Hitachi CMI Probe Compatibility Guide: Models & Part Numbers

The correct Hitachi CMI probe depends on two things: the exact gauge model and the measurement you need to make. An ETP probe for through-hole copper is not interchangeable with an SRP-4 micro-resistance probe for surface copper simply because both connect to a CMI instrument。PCB copper gauges may use different probe technologies for surface copper, fine traces, or plated through-hole copper. Hitachi’s product comparison describes the CMI511 as an eddy-current instrument for through-hole copper, while CMI165 and CMI563 use micro-resistance for surface copper applications. The CMI760 supports multiple PCB copper applications and can use different probe types depending on configuration

1. Identify Your Hitachi CMI Model and Measurement Application

Before purchasing a Hitachi thickness gauge probe, establish what the instrument measures and which measuring system it supports. A probe intended for surface copper measurement cannot automatically replace one designed for plated through-hole copper.

Hitachi and Oxford CMI instruments

Both Hitachi and Oxford CMI names can be found in the industrial thickness measurement market. Older instruments and accessories may carry Oxford Instruments branding, while replacement parts are listed in the Hitachi High-Tech consumables catalog.

When sourcing a replacement Oxford CMI probe, the brand name alone is not sufficient to establish compatibility. The instrument nameplate, serial number, original probe label and manufacturer part number provide more useful purchasing references.

Identify the measurement task

Measurement applicationRelevant CMI instrumentMeasuring technology
Copper foil and laminateCMI95M, CMI165, CMI563, CMI760Microresistance
Surface copper thicknessCMI165, CMI563, CMI760Microresistance
Fine-line copper thicknessCMI165, CMI563, CMI760Microresistance
Electroless copper thicknessCMI165, CMI563, CMI760Microresistance
Plated through-hole copperCMI511, suitably configured CMI760Eddy current

The manufacturer’s PCB copper thickness gauge comparison distinguishes instruments by their supported measurement applications. Digital+1

Information to check before selecting a probe

  • Instrument model: Identify the exact CMI model rather than relying on a general series name.
  • Measurement application: Confirm whether the task involves surface copper, copper traces or PTH copper.
  • Existing probe: Record its type, part number and physical configuration.
  • Instrument version: Check the serial number and supported accessories.
  • Calibration requirements: Identify the reference standards used with the measuring system.

These details help establish whether a replacement thickness gauge probe is suitable for the existing instrument and production application.

Etp Probe (1)

2. ETP, SRP-4 and SRP-T1: Probe Types and Applications

Hitachi CMI measuring accessories differ in their measurement principles, contact configurations and replacement requirements. Understanding these differences helps buyers select the correct accessory without ordering an unnecessary complete probe assembly.

ETP Probe for Through-Hole Copper Measurement

The Hitachi ETP probe is a specialized eddy current probe used to measure copper thickness inside plated through-holes on PCBs.

Unlike general-purpose eddy current probes used for industrial coating inspection or metal testing, the ETP is designed for PCB through-hole copper measurement.

Typical applications include:

  • PTH copper thickness inspection.
  • Electroplating process monitoring.
  • Through-hole copper quality control.
  • Non-destructive PCB copper thickness measurement.

Hitachi lists an ETP probe configuration for applicable instruments in the CMI500 and CMI700 series.

SRP-4 Probe for Surface Copper Measurement

The Hitachi SRP-4 probe uses four-point microresistance technology for PCB surface copper thickness measurement.

In four point probe measurement, separate electrical contacts are used for current injection and voltage measurement, reducing the influence of contact resistance on the measured electrical response.

Although the SRP-4 follows the general principles of a 4 point probe, it is a dedicated copper thickness measurement accessory rather than a universal four-point resistance probe.

Available SRP-4 configurations include:

ConfigurationStandard versionNarrow version
Manufacturer-listed spacing9.4 mm5.3 mm
Contact footprintRelatively largerRelatively smaller
Typical applicationGeneral surface copper measurementRestricted measurement areas
Selection requirementCompatible probe and instrumentCompatible probe and instrument

SRP-T1 Replacement Tips for CMI165

The SRP-T1 is a replacement measuring tip designed for the CMI165. It is not a complete external probe assembly or a general substitute for SRP-4 replacement tips.

When the measuring contacts become worn, damaged or unreliable, replacing the appropriate SRP-T1 tips may restore normal operation, provided the remaining measuring system is functioning correctly.

ETP vs SRP-4 vs SRP-T1

ProductMeasurement applicationTechnologyAccessory type
ETP ProbeThrough-hole copperEddy currentProbe assembly
SRP-4 ProbeSurface copperMicroresistanceProbe assembly
SRP-4 TipsSurface copperMicroresistance systemReplacement tips
SRP-T1 TipsCMI165 surface and trace copperMicroresistance systemReplacement tips

The most important distinction is the measurement function and supported equipment configuration, rather than the external appearance of the accessory.

3. Hitachi CMI Probe Part Numbers and Cross-Reference Chart

Original manufacturer part numbers provide a reliable starting point when sourcing Hitachi CMI spare parts. They help distinguish complete probe assemblies, different instrument series, replacement tip configurations and associated calibration standards.

This is particularly useful when purchasing accessories for legacy Oxford CMI equipment or replacing a probe that has been in service for several years.

ETP and SRP-4 Probe Assembly Part Numbers

Part NumberProductListed instrument seriesSpecification
10003192ETP ProbeCMI500 / CMI700Through-hole copper
10002859SRP-4 Standard ProbeCMI5009.4 mm
10003035SRP-4 Standard ProbeCMI7009.4 mm
10003036SRP-4 Narrow ProbeCMI7005.3 mm

The SRP-4 standard probe 10002859 and SRP-4 probe 10003035 share the same listed spacing but have different part numbers. Buyers should retain this distinction when requesting quotations for complete probe assemblies.

SRP-4 and SRP-T1 Replacement Tip Part Numbers

Part NumberProductSpecification
10003099SRP-4 Standard Replacement Tips9.4 mm
10003094SRP-4 Narrow Replacement Tips5.3 mm
10003276SRP-T1 Replacement TipCMI165
10003277SRP-T1 Replacement TipsCMI165

When ordering SRP-4 replacement tips, confirm whether the installed probe uses the standard or narrow configuration. For CMI165 replacement tips, use the corresponding SRP-T1 reference.

Related Calibration Standard Part Numbers

Part NumberProductApplication
10002961ETP Verification and Calibration StandardETP through-hole copper measurement

These Hitachi CMI probe part numbers are original manufacturer references. They should not be interpreted as confirmation that every third-party replacement carrying the same reference has been tested or approved by the original manufacturer.

4. Hitachi CMI Probe Compatibility Chart by Model

Instrument compatibility depends on both the measurement function and the specific accessory configuration.

The following Hitachi CMI probe compatibility chart separates manufacturer-listed applications from replacement configurations that require additional verification.

Hitachi CMI instrument and probe compatibility

InstrumentMeasurement applicationProbe or accessoryCompatibility status
CMI95MCopper foil and laminateOriginal measuring systemInstrument-specific
CMI165Surface and trace copperSRP-T1 TipsManufacturer-listed
CMI511PTH copperDedicated eddy current systemConfirm replacement reference
CMI563Surface copperSRP-4 measuring systemConfirm assembly version
CMI500 SeriesPTH copperETP 10003192Listed for applicable instruments
CMI500 SeriesSurface copperSRP-4 10002859Series-level listing
CMI700 SeriesPTH copperETP 10003192Listed for applicable instruments
CMI700 SeriesSurface copperSRP-4 10003035 / 10003036Series-level listing
CMI760Surface copperSRP-4 ProbeSupported configuration
CMI760PTH copperOptional ETP ProbeConfiguration-dependent

CMI500 Series Probe Compatibility

The CMI500 series includes instruments with different measurement functions. Hitachi lists ETP and standard SRP-4 accessories for applicable instruments within this series.

However, CMI511 and CMI563 serve different measurement tasks:

  • CMI511: Dedicated to plated through-hole copper measurement. Confirm the approved replacement probe reference before ordering an external ETP assembly.
  • CMI563: Uses microresistance for surface copper measurement. The CMI500-series SRP-4 probe 10002859 is a relevant catalog reference, subject to confirmation of the installed configuration.

Buyers searching for a CMI500 ETP probe or CMI563 SRP-4 probe should provide the exact instrument model and existing part number.

CMI700 and CMI760 Probe Compatibility

The CMI760 provides surface and through-hole copper measurement capabilities through the appropriate measuring configuration.

Relevant CMI700-series accessories include the ETP probe 10003192, standard SRP-4 probe 10003035 and narrow SRP-4 probe 10003036.

When purchasing a CMI700 ETP probe, CMI760 ETP probe or CMI760 SRP-4 probe, confirm that the instrument supports the requested measuring configuration.

CMI165 and SRP-T1 Compatibility

The CMI165 uses its designated SRP-T1 replacement tips for surface and trace copper measurement. These accessories should be ordered according to the CMI165 part references rather than general four-point probe specifications.

What Can and Cannot Be Concluded from Compatibility Listings

Available informationWhat it confirmsWhat it does not confirm
Same ETP part numberA shared catalog referenceCompatibility with every instrument version
Same SRP-4 spacingMatching listed spacingComplete probe interchangeability
Same connectorPossible physical connectionElectrical or measurement compatibility
Hitachi and Oxford brandingPossible shared product lineageUniversal compatibility
Same CMI seriesA product-family referenceSupport by every model in that family
Same measurement technologySimilar underlying principleIdentical calibration or measurement performance

A series-level compatibility listing is a starting point for purchasing, not a substitute for model-specific verification.

5. How to Confirm and Order the Correct Replacement Probe

Purchasing the correct Hitachi CMI replacement probe requires identifying both the equipment configuration and the component that needs replacement. Ordering a complete probe assembly may be unnecessary if the problem is limited to replaceable measuring contacts.

Complete Probe Assembly or Replacement Tips?

Existing conditionRecommended purchasing consideration
Damaged ETP probe assemblyConfirm the compatible ETP replacement
Damaged SRP-4 probe body or cableEvaluate complete probe replacement
Worn SRP-4 measuring contactsCheck suitable replacement tips
Damaged 9.4 mm SRP-4 tipsStandard replacement tips 10003099
Damaged 5.3 mm SRP-4 tipsNarrow replacement tips 10003094
Worn CMI165 measuring contactsSRP-T1 replacement tips
Damaged or missing calibration standardMatching calibration standard

Measurement instability does not always indicate probe failure. Contamination, unsuitable samples, damaged reference standards and incorrect instrument settings should also be investigated before purchasing replacement parts.

Replacement Probe RFQ Checklist

When contacting a Hitachi CMI probe supplier, provide the following information to support compatibility assessment and quotation.

Purchasing informationRequired details
Instrument BrandHitachi or Oxford Instruments
Instrument ModelCMI165, CMI511, CMI563, CMI700, CMI760 or legacy model
Serial NumberInstrument identification number
Existing Part NumberOriginal probe or tip reference
Probe TypeETP, SRP-4 or SRP-T1-related accessory
Pin Spacing9.4 mm or 5.3 mm, where applicable
ConnectorConnector configuration and photographs
Measurement ApplicationSurface, trace or through-hole copper
Measurement RangeRequired copper thickness range
Calibration StandardsExisting reference standards
Product ConditionGenuine OEM, compatible or refurbished
Order QuantityRequired purchasing quantity

For older Oxford CMI instruments, photographs of the instrument nameplate, existing probe and connector can be particularly useful when the original part number is missing or unreadable.

Confirm OEM and Compatible Replacement Parts

A replacement probe advertised against an original manufacturer part number may be a genuine OEM accessory, a third-party compatible product or a refurbished component.

Before approving the purchase, confirm:

  • The supplied part number and corresponding original reference.
  • The instrument models for which compatibility has been established.
  • The product condition and manufacturer.
  • Available inspection or measurement verification records.
  • Required calibration accessories and procedures.
  • Warranty terms, lead time and replacement support.

A matching part number reference does not, by itself, establish original manufacturer status or equivalent measurement performance. Buyers should request clear documentation when purchasing compatible Hitachi CMI spare parts.

6. Calibration, Verification and Troubleshooting After Probe Replacement

Replacing a coating thickness gauge probe or its measuring tips can change the measurement response of the instrument. Before returning the equipment to PCB production or quality control, perform the calibration or verification procedures specified for the measuring system.

Calibration and Verification Requirements

A practical post-replacement verification process includes:

  1. Confirm the correct probe type, part number and instrument configuration.
  2. Inspect the connector, cable and measuring contacts.
  3. Select the appropriate calibration or verification standard.
  4. Perform calibration where required by the instrument procedure.
  5. Measure the reference standard and check the results against its assigned value and applicable acceptance limits.
  6. Repeat measurements to evaluate consistency before releasing the equipment for production.

ETP probe calibration requires suitable through-hole copper reference standards, whereas SRP-4 measurement requires appropriate surface copper standards.

When selecting Hitachi CMI calibration standards, match the measurement technology, reference thickness, instrument configuration and applicable traceability requirements.

Common Problems After Probe Replacement

ProblemPossible causeRecommended check
Instrument does not detect the probeIncorrect configuration or connectionInstrument model, connector and probe reference
Calibration failureUnsuitable reference standard or probe problemCalibration standard and measuring system
Unstable readingsContamination or inconsistent contactProbe tips and sample surface
Incorrect thickness readingsIncorrect measurement settings or calibrationMeasurement mode and reference values
Poor repeatabilityWorn contacts or inconsistent sample conditionsProbe condition and measurement technique
Readings differ from the previous probeDifferent measurement response or configurationPart number, calibration and verification results

Maintaining records of probe replacements, calibration results and reference measurements also helps equipment engineers identify recurring measurement problems and plan future spare parts purchases.

Conclusion

Selecting the correct Hitachi CMI probe depends on the instrument model, measurement task, original part number and supported measuring configuration. ETP probes, SRP-4 probes and SRP-T1 replacement tips serve different applications and should not be treated as universally interchangeable accessories.

FAQ

Can CMI500 and CMI700 use the same ETP probe?

Hitachi lists ETP probe 10003192 for both the CMI500 and CMI700 series. However, the specific instrument must support the ETP measuring configuration. Confirm the exact model and original accessory reference before ordering.

Which SRP-4 probe is compatible with CMI563?

The CMI563 uses a microresistance measuring system for surface copper. The CMI500-series standard SRP-4 probe 10002859 is a relevant manufacturer-listed reference. Confirm the installed probe assembly and equipment version before purchasing.

Does CMI760 support both ETP and SRP-4 probes?

Yes. The CMI760 supports surface copper measurement through its SRP-4 configuration and through-hole copper measurement through the optional ETP configuration.

Are CMI500 and CMI700 SRP-4 probes interchangeable?

Interchangeability should not be assumed. The standard CMI500-series and CMI700-series SRP-4 assemblies have different manufacturer part numbers, despite sharing the same listed spacing.

Are SRP-T1 and SRP-4 replacement tips interchangeable?

No general interchangeability is established. SRP-T1 tips are intended for the CMI165, while SRP-4 replacement tips are designed for their corresponding SRP-4 configurations.

Is calibration required after replacing a CMI probe?

Follow the instrument manufacturer’s calibration and verification requirements. A successful physical connection does not demonstrate that the instrument is producing accurate or repeatable copper thickness measurements.