The correct Hitachi CMI probe depends on two things: the exact gauge model and the measurement you need to make. An ETP probe for through-hole copper is not interchangeable with an SRP-4 micro-resistance probe for surface copper simply because both connect to a CMI instrument。PCB copper gauges may use different probe technologies for surface copper, fine traces, or plated through-hole copper. Hitachi’s product comparison describes the CMI511 as an eddy-current instrument for through-hole copper, while CMI165 and CMI563 use micro-resistance for surface copper applications. The CMI760 supports multiple PCB copper applications and can use different probe types depending on configuration
1. Identify Your Hitachi CMI Model and Measurement Application
Before purchasing a Hitachi thickness gauge probe, establish what the instrument measures and which measuring system it supports. A probe intended for surface copper measurement cannot automatically replace one designed for plated through-hole copper.
Hitachi and Oxford CMI instruments
Both Hitachi and Oxford CMI names can be found in the industrial thickness measurement market. Older instruments and accessories may carry Oxford Instruments branding, while replacement parts are listed in the Hitachi High-Tech consumables catalog.
When sourcing a replacement Oxford CMI probe, the brand name alone is not sufficient to establish compatibility. The instrument nameplate, serial number, original probe label and manufacturer part number provide more useful purchasing references.
Identify the measurement task
| Measurement application | Relevant CMI instrument | Measuring technology |
|---|---|---|
| Copper foil and laminate | CMI95M, CMI165, CMI563, CMI760 | Microresistance |
| Surface copper thickness | CMI165, CMI563, CMI760 | Microresistance |
| Fine-line copper thickness | CMI165, CMI563, CMI760 | Microresistance |
| Electroless copper thickness | CMI165, CMI563, CMI760 | Microresistance |
| Plated through-hole copper | CMI511, suitably configured CMI760 | Eddy current |
The manufacturer’s PCB copper thickness gauge comparison distinguishes instruments by their supported measurement applications. Digital+1
Information to check before selecting a probe
- Instrument model: Identify the exact CMI model rather than relying on a general series name.
- Measurement application: Confirm whether the task involves surface copper, copper traces or PTH copper.
- Existing probe: Record its type, part number and physical configuration.
- Instrument version: Check the serial number and supported accessories.
- Calibration requirements: Identify the reference standards used with the measuring system.
These details help establish whether a replacement thickness gauge probe is suitable for the existing instrument and production application.

2. ETP, SRP-4 and SRP-T1: Probe Types and Applications
Hitachi CMI measuring accessories differ in their measurement principles, contact configurations and replacement requirements. Understanding these differences helps buyers select the correct accessory without ordering an unnecessary complete probe assembly.
ETP Probe for Through-Hole Copper Measurement
The Hitachi ETP probe is a specialized eddy current probe used to measure copper thickness inside plated through-holes on PCBs.
Unlike general-purpose eddy current probes used for industrial coating inspection or metal testing, the ETP is designed for PCB through-hole copper measurement.
Typical applications include:
- PTH copper thickness inspection.
- Electroplating process monitoring.
- Through-hole copper quality control.
- Non-destructive PCB copper thickness measurement.
Hitachi lists an ETP probe configuration for applicable instruments in the CMI500 and CMI700 series.
SRP-4 Probe for Surface Copper Measurement
The Hitachi SRP-4 probe uses four-point microresistance technology for PCB surface copper thickness measurement.
In four point probe measurement, separate electrical contacts are used for current injection and voltage measurement, reducing the influence of contact resistance on the measured electrical response.
Although the SRP-4 follows the general principles of a 4 point probe, it is a dedicated copper thickness measurement accessory rather than a universal four-point resistance probe.
Available SRP-4 configurations include:
| Configuration | Standard version | Narrow version |
|---|---|---|
| Manufacturer-listed spacing | 9.4 mm | 5.3 mm |
| Contact footprint | Relatively larger | Relatively smaller |
| Typical application | General surface copper measurement | Restricted measurement areas |
| Selection requirement | Compatible probe and instrument | Compatible probe and instrument |
SRP-T1 Replacement Tips for CMI165
The SRP-T1 is a replacement measuring tip designed for the CMI165. It is not a complete external probe assembly or a general substitute for SRP-4 replacement tips.
When the measuring contacts become worn, damaged or unreliable, replacing the appropriate SRP-T1 tips may restore normal operation, provided the remaining measuring system is functioning correctly.
ETP vs SRP-4 vs SRP-T1
| Product | Measurement application | Technology | Accessory type |
|---|---|---|---|
| ETP Probe | Through-hole copper | Eddy current | Probe assembly |
| SRP-4 Probe | Surface copper | Microresistance | Probe assembly |
| SRP-4 Tips | Surface copper | Microresistance system | Replacement tips |
| SRP-T1 Tips | CMI165 surface and trace copper | Microresistance system | Replacement tips |
The most important distinction is the measurement function and supported equipment configuration, rather than the external appearance of the accessory.
3. Hitachi CMI Probe Part Numbers and Cross-Reference Chart
Original manufacturer part numbers provide a reliable starting point when sourcing Hitachi CMI spare parts. They help distinguish complete probe assemblies, different instrument series, replacement tip configurations and associated calibration standards.
This is particularly useful when purchasing accessories for legacy Oxford CMI equipment or replacing a probe that has been in service for several years.
ETP and SRP-4 Probe Assembly Part Numbers
| Part Number | Product | Listed instrument series | Specification |
|---|---|---|---|
| 10003192 | ETP Probe | CMI500 / CMI700 | Through-hole copper |
| 10002859 | SRP-4 Standard Probe | CMI500 | 9.4 mm |
| 10003035 | SRP-4 Standard Probe | CMI700 | 9.4 mm |
| 10003036 | SRP-4 Narrow Probe | CMI700 | 5.3 mm |
The SRP-4 standard probe 10002859 and SRP-4 probe 10003035 share the same listed spacing but have different part numbers. Buyers should retain this distinction when requesting quotations for complete probe assemblies.
SRP-4 and SRP-T1 Replacement Tip Part Numbers
| Part Number | Product | Specification |
|---|---|---|
| 10003099 | SRP-4 Standard Replacement Tips | 9.4 mm |
| 10003094 | SRP-4 Narrow Replacement Tips | 5.3 mm |
| 10003276 | SRP-T1 Replacement Tip | CMI165 |
| 10003277 | SRP-T1 Replacement Tips | CMI165 |
When ordering SRP-4 replacement tips, confirm whether the installed probe uses the standard or narrow configuration. For CMI165 replacement tips, use the corresponding SRP-T1 reference.
Related Calibration Standard Part Numbers
| Part Number | Product | Application |
|---|---|---|
| 10002961 | ETP Verification and Calibration Standard | ETP through-hole copper measurement |
These Hitachi CMI probe part numbers are original manufacturer references. They should not be interpreted as confirmation that every third-party replacement carrying the same reference has been tested or approved by the original manufacturer.
4. Hitachi CMI Probe Compatibility Chart by Model
Instrument compatibility depends on both the measurement function and the specific accessory configuration.
The following Hitachi CMI probe compatibility chart separates manufacturer-listed applications from replacement configurations that require additional verification.
Hitachi CMI instrument and probe compatibility
| Instrument | Measurement application | Probe or accessory | Compatibility status |
|---|---|---|---|
| CMI95M | Copper foil and laminate | Original measuring system | Instrument-specific |
| CMI165 | Surface and trace copper | SRP-T1 Tips | Manufacturer-listed |
| CMI511 | PTH copper | Dedicated eddy current system | Confirm replacement reference |
| CMI563 | Surface copper | SRP-4 measuring system | Confirm assembly version |
| CMI500 Series | PTH copper | ETP 10003192 | Listed for applicable instruments |
| CMI500 Series | Surface copper | SRP-4 10002859 | Series-level listing |
| CMI700 Series | PTH copper | ETP 10003192 | Listed for applicable instruments |
| CMI700 Series | Surface copper | SRP-4 10003035 / 10003036 | Series-level listing |
| CMI760 | Surface copper | SRP-4 Probe | Supported configuration |
| CMI760 | PTH copper | Optional ETP Probe | Configuration-dependent |
CMI500 Series Probe Compatibility
The CMI500 series includes instruments with different measurement functions. Hitachi lists ETP and standard SRP-4 accessories for applicable instruments within this series.
However, CMI511 and CMI563 serve different measurement tasks:
- CMI511: Dedicated to plated through-hole copper measurement. Confirm the approved replacement probe reference before ordering an external ETP assembly.
- CMI563: Uses microresistance for surface copper measurement. The CMI500-series SRP-4 probe 10002859 is a relevant catalog reference, subject to confirmation of the installed configuration.
Buyers searching for a CMI500 ETP probe or CMI563 SRP-4 probe should provide the exact instrument model and existing part number.
CMI700 and CMI760 Probe Compatibility
The CMI760 provides surface and through-hole copper measurement capabilities through the appropriate measuring configuration.
Relevant CMI700-series accessories include the ETP probe 10003192, standard SRP-4 probe 10003035 and narrow SRP-4 probe 10003036.
When purchasing a CMI700 ETP probe, CMI760 ETP probe or CMI760 SRP-4 probe, confirm that the instrument supports the requested measuring configuration.
CMI165 and SRP-T1 Compatibility
The CMI165 uses its designated SRP-T1 replacement tips for surface and trace copper measurement. These accessories should be ordered according to the CMI165 part references rather than general four-point probe specifications.
What Can and Cannot Be Concluded from Compatibility Listings
| Available information | What it confirms | What it does not confirm |
|---|---|---|
| Same ETP part number | A shared catalog reference | Compatibility with every instrument version |
| Same SRP-4 spacing | Matching listed spacing | Complete probe interchangeability |
| Same connector | Possible physical connection | Electrical or measurement compatibility |
| Hitachi and Oxford branding | Possible shared product lineage | Universal compatibility |
| Same CMI series | A product-family reference | Support by every model in that family |
| Same measurement technology | Similar underlying principle | Identical calibration or measurement performance |
A series-level compatibility listing is a starting point for purchasing, not a substitute for model-specific verification.
5. How to Confirm and Order the Correct Replacement Probe
Purchasing the correct Hitachi CMI replacement probe requires identifying both the equipment configuration and the component that needs replacement. Ordering a complete probe assembly may be unnecessary if the problem is limited to replaceable measuring contacts.
Complete Probe Assembly or Replacement Tips?
| Existing condition | Recommended purchasing consideration |
|---|---|
| Damaged ETP probe assembly | Confirm the compatible ETP replacement |
| Damaged SRP-4 probe body or cable | Evaluate complete probe replacement |
| Worn SRP-4 measuring contacts | Check suitable replacement tips |
| Damaged 9.4 mm SRP-4 tips | Standard replacement tips 10003099 |
| Damaged 5.3 mm SRP-4 tips | Narrow replacement tips 10003094 |
| Worn CMI165 measuring contacts | SRP-T1 replacement tips |
| Damaged or missing calibration standard | Matching calibration standard |
Measurement instability does not always indicate probe failure. Contamination, unsuitable samples, damaged reference standards and incorrect instrument settings should also be investigated before purchasing replacement parts.
Replacement Probe RFQ Checklist
When contacting a Hitachi CMI probe supplier, provide the following information to support compatibility assessment and quotation.
| Purchasing information | Required details |
|---|---|
| Instrument Brand | Hitachi or Oxford Instruments |
| Instrument Model | CMI165, CMI511, CMI563, CMI700, CMI760 or legacy model |
| Serial Number | Instrument identification number |
| Existing Part Number | Original probe or tip reference |
| Probe Type | ETP, SRP-4 or SRP-T1-related accessory |
| Pin Spacing | 9.4 mm or 5.3 mm, where applicable |
| Connector | Connector configuration and photographs |
| Measurement Application | Surface, trace or through-hole copper |
| Measurement Range | Required copper thickness range |
| Calibration Standards | Existing reference standards |
| Product Condition | Genuine OEM, compatible or refurbished |
| Order Quantity | Required purchasing quantity |
For older Oxford CMI instruments, photographs of the instrument nameplate, existing probe and connector can be particularly useful when the original part number is missing or unreadable.
Confirm OEM and Compatible Replacement Parts
A replacement probe advertised against an original manufacturer part number may be a genuine OEM accessory, a third-party compatible product or a refurbished component.
Before approving the purchase, confirm:
- The supplied part number and corresponding original reference.
- The instrument models for which compatibility has been established.
- The product condition and manufacturer.
- Available inspection or measurement verification records.
- Required calibration accessories and procedures.
- Warranty terms, lead time and replacement support.
A matching part number reference does not, by itself, establish original manufacturer status or equivalent measurement performance. Buyers should request clear documentation when purchasing compatible Hitachi CMI spare parts.
6. Calibration, Verification and Troubleshooting After Probe Replacement
Replacing a coating thickness gauge probe or its measuring tips can change the measurement response of the instrument. Before returning the equipment to PCB production or quality control, perform the calibration or verification procedures specified for the measuring system.
Calibration and Verification Requirements
A practical post-replacement verification process includes:
- Confirm the correct probe type, part number and instrument configuration.
- Inspect the connector, cable and measuring contacts.
- Select the appropriate calibration or verification standard.
- Perform calibration where required by the instrument procedure.
- Measure the reference standard and check the results against its assigned value and applicable acceptance limits.
- Repeat measurements to evaluate consistency before releasing the equipment for production.
ETP probe calibration requires suitable through-hole copper reference standards, whereas SRP-4 measurement requires appropriate surface copper standards.
When selecting Hitachi CMI calibration standards, match the measurement technology, reference thickness, instrument configuration and applicable traceability requirements.
Common Problems After Probe Replacement
| Problem | Possible cause | Recommended check |
|---|---|---|
| Instrument does not detect the probe | Incorrect configuration or connection | Instrument model, connector and probe reference |
| Calibration failure | Unsuitable reference standard or probe problem | Calibration standard and measuring system |
| Unstable readings | Contamination or inconsistent contact | Probe tips and sample surface |
| Incorrect thickness readings | Incorrect measurement settings or calibration | Measurement mode and reference values |
| Poor repeatability | Worn contacts or inconsistent sample conditions | Probe condition and measurement technique |
| Readings differ from the previous probe | Different measurement response or configuration | Part number, calibration and verification results |
Maintaining records of probe replacements, calibration results and reference measurements also helps equipment engineers identify recurring measurement problems and plan future spare parts purchases.

Conclusion
Selecting the correct Hitachi CMI probe depends on the instrument model, measurement task, original part number and supported measuring configuration. ETP probes, SRP-4 probes and SRP-T1 replacement tips serve different applications and should not be treated as universally interchangeable accessories.
FAQ
Can CMI500 and CMI700 use the same ETP probe?
Hitachi lists ETP probe 10003192 for both the CMI500 and CMI700 series. However, the specific instrument must support the ETP measuring configuration. Confirm the exact model and original accessory reference before ordering.
Which SRP-4 probe is compatible with CMI563?
The CMI563 uses a microresistance measuring system for surface copper. The CMI500-series standard SRP-4 probe 10002859 is a relevant manufacturer-listed reference. Confirm the installed probe assembly and equipment version before purchasing.
Does CMI760 support both ETP and SRP-4 probes?
Yes. The CMI760 supports surface copper measurement through its SRP-4 configuration and through-hole copper measurement through the optional ETP configuration.
Are CMI500 and CMI700 SRP-4 probes interchangeable?
Interchangeability should not be assumed. The standard CMI500-series and CMI700-series SRP-4 assemblies have different manufacturer part numbers, despite sharing the same listed spacing.
Are SRP-T1 and SRP-4 replacement tips interchangeable?
No general interchangeability is established. SRP-T1 tips are intended for the CMI165, while SRP-4 replacement tips are designed for their corresponding SRP-4 configurations.
Is calibration required after replacing a CMI probe?
Follow the instrument manufacturer’s calibration and verification requirements. A successful physical connection does not demonstrate that the instrument is producing accurate or repeatable copper thickness measurements.