Ionic Contamination tester for PCB cleaning
$12000 – $16000
Ionic Contamination Tester for PCB cleaning is a precision analytical instrument used to quantify the level of soluble ionic residues remaining on a cleaned PCB surface, ensuring compliance with industry cleanliness standards and preventing failures related to corrosion or electrochemical migration.
1.Ionic Contamination tester for PCB cleaning
The Ionic Contamination Tester is a special device used to measure the degree of ion contamination on the surface of items such as PCB (printed circuit board), PCBA (printed circuit board assembly), electronic components, etc. It indirectly reflects the degree of ion contamination by cleaning the surface of the tested item, dissolving the ion contaminants into a specific solution, and then using a conductivity meter to test the conductivity of the solution.
2.Ionic contamination analyzer feature
Testing PCB size range: WELL-ICT01: 50*50MM-350*650MM
WELL-ICT02:100*100MM-650*650MM
Testing accuracy: ±5%
Testing method: Dynamic/Static
Heating device:heating rod 220V/1600W
Data control mode:COM port RS232 communication
Proportion and volume of the extracted liquid: 3(Isopropyl alcohol) :1 (Deionized water) total about 32L (WELL-ICT02)
3.Application scenarios
Electronic manufacturing industry: In the PCB and PCBA production process, it is used to detect the cleaning effect, ensure the surface cleanliness of the product, and improve product quality.
PCB contamination tester Applied Standard: IPC-TM650
| Name | Ionic contamination tester | Ionic contamination tester |
| Model | WELL-ICT01 | WELL-ICT02 |
| Testing Mothod | Static /Dynamic | Static /Dynamic |
| Testing accuracy | ±5% of full scale | ±5% of full scale |
| Extraction volume | around 17L | around 32L |
| Specific gravity of extract | 0.85-0.855 | 0.85-0.855 |
| Working temp | 5-36℃ | 5-36℃ |
| Extraction temp | 40±2℃ | 40±2℃ |
| Conductivity analysis rate | 0.001μs/cm² | 0.001μs/cm² |
| Electrode resolution range | 0.001μs/cm² | 0.001μs/cm² |
| Electrical conductivity teste benchmark | 55-66 ohm | 55-66 ohm |
| Testing PCB size | 100*100mm-350*650*60mm | 50*50mm-650*350mm |
| Tank size | 660*360*65mm(L*W*H) | 700X700X65mm(L*W*H) |
| Software languare | Chinese/English | Chinese/English |
| Packing | Wooden case | Wooden case |
| Power | 1600W | 1600W |
| Power supply | 220VAC,50HZ | 220VAC,50HZ |
4.Maintenance points
Regular calibration: Calibrate the conductivity sensor regularly according to the instructions to ensure measurement accuracy.
Cleaning and maintenance: After the test is completed, clean the test tank and sensor in time to prevent residual solution from corroding the equipment.
Environmental requirements: Place the ion contamination tester in a dry, ventilated environment without corrosive gases to prevent the equipment from getting damp or damaged.