{"id":1177,"date":"2025-12-04T13:04:33","date_gmt":"2025-12-04T13:04:33","guid":{"rendered":"https:\/\/welleltron.com\/?post_type=product&#038;p=1177"},"modified":"2025-12-26T08:33:45","modified_gmt":"2025-12-26T08:33:45","slug":"hitachi-srp-4-calibration-standard","status":"publish","type":"product","link":"https:\/\/welleltron.com\/vi\/test-equipment\/calibration-standard-plate\/hitachi-srp-4-calibration-standard\/","title":{"rendered":"Original Hitachi SRP-4 Calibration Standard ETP Standard"},"content":{"rendered":"<h2>Hitachi calibrate stand Overview<\/h2>\n<p data-path-to-node=\"1\">Hitachi SRP-4 Calibration Standard (also called Cmi500 Calibration Standard and Cmi700 Calibration Standard and PTH Hole <span class=\"keywords_replace\">calibration standard plate<\/span>) is a core precision tool for PCB thru-hole copper thickness testing. Specifically designed for Hitachi CMI500 Hole Cu Thickness Tester (specialized in hole copper detection) and <a href=\"https:\/\/welleltron.com\/vi\/thickness-gauges\/\">CMI700<\/a> Cu Thickness Tester (dual-purpose for surface and hole copper), it serves as a &#8220;reference benchmark&#8221; to correct gauge drift over time\u2014critical for reliable data in PCB electroplating and quality control. Made of high-purity copper with precision-drilled thru-holes (matching PCB PTH hole specifications), this Calibration Standard Plate eliminates measurement deviations caused by uncalibrated equipment. As part of our one-stop PCB testing solutions, it works seamlessly with PTH Hole <a href=\"https:\/\/welleltron.com\/vi\/machinery-spare-parts\/etp-probe\/oxford-cmi500-etp-probe\/\">ETP Probe<\/a> (for hole copper testing), providing comprehensive support for PCB factories and testing labs.<\/p>\n<h2 data-path-to-node=\"6\">Material Technology and Certified Values<\/h2>\n<p data-path-to-node=\"7\">The integrity of the <b>Calibration Standard Plate<\/b> is defined by its material construction and the rigor of its certification.<\/p>\n<h3 data-path-to-node=\"8\">1. Material Construction<\/h3>\n<p data-path-to-node=\"9\">The plate replicates the geometry and material composition of a real PCB being measured:<\/p>\n<ul data-path-to-node=\"10\">\n<li>\n<p data-path-to-node=\"10,0,0\"><b>Substrate:<\/b> Typically a non-conductive, high-grade laminate material (similar to FR4) to simulate the actual product environment.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"10,1,0\"><b>Coating:<\/b> Features highly uniform <b>Certified Thickness<\/b> layers of pure copper. These copper layers are deposited under strict quality control to ensure minimal variation across the standard&#8217;s surface.<\/p>\n<\/li>\n<\/ul>\n<h3 data-path-to-node=\"11\">2. Certified Thicknesses<\/h3>\n<p data-path-to-node=\"12\">The set usually comprises multiple plates, each representing a distinct, critical thickness point across the SRP-4&#8217;s operating range (e.g., <span class=\"math-inline\" data-math=\"5 \\mu\\text{m}\">5\u03bcm<\/span>, <span class=\"math-inline\" data-math=\"18 \\mu\\text{m}\">18\u03bcm<\/span>, <span class=\"math-inline\" data-math=\"35 \\mu\\text{m}\">35\u03bcm<\/span>, <span class=\"math-inline\" data-math=\"70 \\mu\\text{m}\">70\u03bcm<\/span>). These values are verified by independent, high-accuracy methods.<\/p>\n<h2 data-path-to-node=\"13\">Key Features and Essential Role<\/h2>\n<p data-path-to-node=\"14\">The <b>Hitachi SRP-4 Calibration Standard<\/b> plays a non-negotiable role in PCB Quality Control (QC).<\/p>\n<ul data-path-to-node=\"15\">\n<li>\n<p data-path-to-node=\"15,0,0\"><b>Establishing Zero and Span:<\/b> The standard set is used to define both the <i>zero point<\/i> (unplated substrate) and the <i>span<\/i> (the maximum thickness) of the gauge, ensuring the entire measurement curve is accurate.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"15,1,0\"><b>Eliminating Drift:<\/b> Regular use of the standard plate compensates for environmental factors (temperature, humidity) and electronic drift within the CMI instrument, ensuring long-term measurement consistency.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"15,2,0\"><b>Post-Maintenance Verification:<\/b> After any significant event, such as SRP-4 Probe replacement or instrument servicing, the Standard Plate is the first item measured to confirm operational accuracy before production testing resumes.<\/p>\n<\/li>\n<\/ul>\n<h2 data-path-to-node=\"16\">Application<\/h2>\n<p data-path-to-node=\"17\">The primary usage is confined to the Surface Finishing Industry and Electronics Manufacturing.<\/p>\n<table data-path-to-node=\"18\">\n<thead>\n<tr>\n<td><strong>Application Scenario<\/strong><\/td>\n<td><strong>Search terms<\/strong><\/td>\n<td><strong>Value Delivered<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span data-path-to-node=\"18,1,0,0\"><b>Routine QC Checks<\/b><\/span><\/td>\n<td><span data-path-to-node=\"18,1,1,0\"><b>Calibration Standard Plate<\/b> \/ <b>Standard Calibration Plate<\/b><\/span><\/td>\n<td><span data-path-to-node=\"18,1,2,0\">Ensures that every measurement taken during a production run is accurate and verifiable, reducing scrap rates.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"18,2,0,0\"><b>New Probe Installation<\/b><\/span><\/td>\n<td><span data-path-to-node=\"18,2,1,0\"><b>CMI700 Calibration Standard<\/b> \/ <b>SRP-4 Calibration Kit<\/b><\/span><\/td>\n<td><span data-path-to-node=\"18,2,2,0\">Essential for setting the gain and offset of the new probe, guaranteeing its initial <span class=\"math-inline\" data-math=\"\\pm 1\\%\">\u00a01% <\/span>accuracy.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"18,3,0,0\"><b>Compliance &amp; Audits<\/b><\/span><\/td>\n<td><span data-path-to-node=\"18,3,1,0\"><b>NIST Traceable Copper Thickness Standard<\/b><\/span><\/td>\n<td><span data-path-to-node=\"18,3,2,0\">Provides the necessary documentation and traceability required for ISO 9001 and high-reliability industry audits (e.g., automotive).<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"18,4,0,0\"><b>Technical Research<\/b><\/span><\/td>\n<td><span data-path-to-node=\"18,4,1,0\"><b>Calibration Plate Meaning<\/b> \/ <b>Calibration Standard Definition<\/b><\/span><\/td>\n<td><span data-path-to-node=\"18,4,2,0\">Used to define and validate the accuracy limits of new PCB materials or plating processes.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div>\n<h2><strong>FAQ<\/strong><\/h2>\n<div>\n<div>Q1: How often should the standard be re-calibrated?<\/div>\n<div>A1: Recommend re-verification every 2 years (per industry norms); we offer professional re-calibration services for expired standards.<\/div>\n<div><\/div>\n<div>Q2: What if the thru-holes get blocked by dust?<\/div>\n<div>A2: Use a soft-bristle Nylon Brush to gently clean the holes\u2014avoid sharp tools that scratch the hole copper and affect accuracy.<\/div>\n<div><\/div>\n<div>Q3: Is it compatible with third-party ETP Probes?<\/div>\n<div>A3: Works best with original Hitachi PTH Hole ETP Probes; third-party probes may have different tip sizes, leading to calibration inconsistencies.<\/div>\n<div><\/div>\n<div>Q4: Can it test blind\/buried holes?<\/div>\n<div>A4: No\u2014it\u2019s for thru-holes. For blind\/buried hole calibration, contact us for customized standards matching those hole types.<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Hitachi SRP-4 Calibration Standard is used to accurately calibrate SRP-4 micro-resistance probes, ensuring precise and repeatable copper thickness measurements on printed circuit boards<\/p>\n<p><strong>Material: <\/strong>High-purity electrolytic copper<br \/>\n<strong>Dimensions\uff1a<\/strong>3&#8243;\u00d73&#8243;<\/p>","protected":false},"featured_media":2225,"template":"","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_brand":[],"product_cat":[66,61],"product_tag":[],"class_list":{"0":"post-1177","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-calibration-standard-plate","7":"product_cat-test-equipment","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple","14":"entry","15":"content-bg","16":"loop-entry"},"taxonomy_info":{"product_cat":[{"value":66,"label":"Hitachi calibration standard plate"},{"value":61,"label":"Test equipment"}]},"featured_image_src_large":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/\u6807\u51c6\u7247calibration-standard.png",850,850,false],"author_info":[],"comment_info":"","_links":{"self":[{"href":"https:\/\/welleltron.com\/vi\/wp-json\/wp\/v2\/product\/1177","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/welleltron.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/welleltron.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/welleltron.com\/vi\/wp-json\/wp\/v2\/media\/2225"}],"wp:attachment":[{"href":"https:\/\/welleltron.com\/vi\/wp-json\/wp\/v2\/media?parent=1177"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/welleltron.com\/vi\/wp-json\/wp\/v2\/product_brand?post=1177"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/welleltron.com\/vi\/wp-json\/wp\/v2\/product_cat?post=1177"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/welleltron.com\/vi\/wp-json\/wp\/v2\/product_tag?post=1177"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}