{"id":1164,"date":"2025-12-04T12:16:20","date_gmt":"2025-12-04T12:16:20","guid":{"rendered":"https:\/\/welleltron.com\/?post_type=product&#038;p=1164"},"modified":"2025-12-26T08:23:46","modified_gmt":"2025-12-26T08:23:46","slug":"hitachi-srp-4-tips","status":"publish","type":"product","link":"https:\/\/welleltron.com\/ru\/test-equipment\/hitachi-srp-4-tips\/","title":{"rendered":"Hitachi SRP-4 tips"},"content":{"rendered":"<h2>Hitachi SRP-4 tips Overview<\/h2>\n<p data-path-to-node=\"1\"><strong>Hitachi SRP-4 tips<\/strong>\u00a0(also called <strong>Probe Tips<\/strong> or <strong>Srp-4 Probe Tips<\/strong>) are core consumable accessories designed for Hitachi SRP-4 probes\u2014key components of CMI series PCB Cooper Thickness Testers (including CMI563, CMI700, CMI760). Made with high-quality crystal materials, these replacement tips maintain the same measurement precision as the original probe, ensuring consistent accuracy in PCB surface copper thickness testing. As part of our one-stop PCB testing solutions, they seamlessly match other products like <a href=\"https:\/\/welleltron.com\/ru\/machinery-spare-parts\/srp-4-probe\/hitachi-srp-4-probe\/\">SRP-4 probe<\/a>, <a href=\"https:\/\/welleltron.com\/ru\/machinery-spare-parts\/etp-probe\/oxford-cmi500-etp-probe\/\">ETP Probe<\/a> (for hole copper testing), and Nylon brush (for tip cleaning), providing comprehensive support for PCB production quality control.<\/p>\n<h2 data-path-to-node=\"3\">Technical Specifications and Material Science<\/h2>\n<p data-path-to-node=\"4\">The performance of the <b>SRP-4 Contact Tips<\/b> is directly tied to the specialized materials and strict manufacturing tolerances provided by <b>Hitachi High-Tech SRP-4 Tips<\/b>.<\/p>\n<table data-path-to-node=\"5\">\n<thead>\n<tr>\n<td><strong>Specification<\/strong><\/td>\n<td><strong>Detail<\/strong><\/td>\n<td><strong>Significance<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span data-path-to-node=\"5,1,0,0\"><b>Model\/Compatibility<\/b><\/span><\/td>\n<td><span data-path-to-node=\"5,1,1,0\"><b>SRP-4 Replacement Tips<\/b><\/span><\/td>\n<td><span data-path-to-node=\"5,1,2,0\"><span class=\"math-inline\" data-math=\"100\\%\">$100<\/span>\u00a0compatible with the <b>SRP-4 probe<\/b> body used on CMI563\/<b>CMI700 Tips<\/b>.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"5,2,0,0\"><b>Core Material<\/b><\/span><\/td>\n<td><span data-path-to-node=\"5,2,1,0\">High-purity crystal (Often a specialized <b>Conductive Alloy Tips<\/b> blend)<\/span><\/td>\n<td><span data-path-to-node=\"5,2,2,0\">Ensures stable <b>Micro-Resistance Tips<\/b> performance and consistent <b>eddy current induction<\/b>.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"5,3,0,0\"><b>Measurement Principle<\/b><\/span><\/td>\n<td><span data-path-to-node=\"5,3,1,0\"><b>Four-Point Probe Tips<\/b><\/span><\/td>\n<td><span data-path-to-node=\"5,3,2,0\">Maintains the accuracy needed for <b>Copper Thickness Testing Tips<\/b>.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"5,4,0,0\"><b>Resolution<\/b><\/span><\/td>\n<td><span data-path-to-node=\"5,4,1,0\">Down to <span class=\"math-inline\" data-math=\"0.001 \\text{ mils}\">0.001mils<\/span> (<span class=\"math-inline\" data-math=\"&lt;1 \\mu\\text{m}\">&lt;1\u03bcm<\/span>)<\/span><\/td>\n<td><span data-path-to-node=\"5,4,2,0\">Supports high-precision testing for ultra-thin <b>Electroless Copper<\/b> layers.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"5,5,0,0\"><b>Applicable Range<\/b><\/span><\/td>\n<td><span data-path-to-node=\"5,5,1,0\"><span class=\"math-inline\" data-math=\"0.25 \\mu\\text{m}\">0.25 \u03bcm<\/span>\u00a0to <span class=\"math-inline\" data-math=\"152 \\mu\\text{m}\">152\u03bcm<\/span><\/span><\/td>\n<td><span data-path-to-node=\"5,5,2,0\">Covers the entire spectrum of <b>PCB Measurement Tips<\/b> requirements, from fine lines to thick electroplating.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 data-path-to-node=\"12\">Key Features and Cost Advantages<\/h2>\n<p data-path-to-node=\"13\">Choosing <b>OEM SRP-4 Tips<\/b> over <b>Generic SRP-4 Tips<\/b> offers significant operational and financial benefits for purchasers looking at the <b>SRP-4 Tips price \/ cost<\/b>.<\/p>\n<table data-path-to-node=\"14\">\n<thead>\n<tr>\n<td><strong>Feature<\/strong><\/td>\n<td><strong>Advantage<\/strong><\/td>\n<td><strong>Value to Purchaser<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span data-path-to-node=\"14,1,0,0\"><b>Seamless Compatibility<\/b><\/span><\/td>\n<td><span data-path-to-node=\"14,1,1,0\"><span class=\"math-inline\" data-math=\"100\\%\">100%<\/span>\u00a0compatibility with CMI563\/<b>CMI700 Tips<\/b> testers.<\/span><\/td>\n<td><span data-path-to-node=\"14,1,2,0\">Eliminates performance issues associated with <b>Non-OEM SRP-4 Tips<\/b> and guarantees reliable <b>PCB Measurement Tips<\/b> results.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"14,2,0,0\"><b>Cost Efficiency<\/b><\/span><\/td>\n<td><span data-path-to-node=\"14,2,1,0\">Allows replacement of just the tip (<b>SRP-4 Tips Refill<\/b>), not the entire probe assembly.<\/span><\/td>\n<td><span data-path-to-node=\"14,2,2,0\">Cuts annual probe maintenance costs by over <span class=\"math-inline\" data-math=\"50\\%\">50%<\/span>\u00a0compared to models requiring full probe replacement.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"14,3,0,0\"><b>Quick Turnaround<\/b><\/span><\/td>\n<td><span data-path-to-node=\"14,3,1,0\">On-site replacement can be completed by operators in <span class=\"math-inline\" data-math=\"2\u20133\">2\u20133<\/span>\u00a0minutes.<\/span><\/td>\n<td><span data-path-to-node=\"14,3,2,0\">Minimizes tester downtime, ensuring production continuity and efficiency.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"14,4,0,0\"><b>Consistent Accuracy<\/b><\/span><\/td>\n<td><span data-path-to-node=\"14,4,1,0\"><b>OEM SRP-4 Tips<\/b> maintain the original <span class=\"math-inline\" data-math=\"\\pm 1\\%\">\u00a01%<\/span>\u00a0accuracy standard.<\/span><\/td>\n<td><span data-path-to-node=\"14,4,2,0\">Prevents costly manufacturing rejects due to inaccurate copper thickness data.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 data-path-to-node=\"15\">Application Scenarios<\/h2>\n<p data-path-to-node=\"16\">These precision <b>SRP-4 Probe Tips<\/b> are essential across high-reliability Electronics Manufacturing sectors:<\/p>\n<ul data-path-to-node=\"17\">\n<li>\n<p data-path-to-node=\"17,0,0\"><b>High-Density Interconnect (HDI) Production:<\/b> Critical for accurately measuring ultra-thin copper layers (<span class=\"math-inline\" data-math=\"&lt;1 \\mu\\text{m}\">&lt;1 \u03bcm<\/span>) used in micro-vias, where the SRP-4 Crystal Tips may be preferred.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"17,1,0\"><b>Automotive\/Aerospace PCB:<\/b> Used in PCB Quality Control (QC) to verify that heavy Electrodeposited Copper meets stringent durability standards.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"17,2,0\"><b>R&amp;D and Laboratory Testing:<\/b> Provides reliable, traceable data for new process development, relying on the stability of the SRP-4 Tip Set.<\/p>\n<\/li>\n<\/ul>\n<h2 data-path-to-node=\"9\">Replacement and Maintenance Protocol<\/h2>\n<p data-path-to-node=\"10\">Proper <b>Probe Tip Maintenance<\/b> ensures the longevity of the SRP-4 Thickness Probe and the accuracy of the CMI gauge.<\/p>\n<ol start=\"1\" data-path-to-node=\"11\">\n<li>\n<p data-path-to-node=\"11,0,0\"><b>Preparation:<\/b> Turn off the tester and disconnect the SRP-4 probe. Clean the probe base with a Nylon Brush.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"11,1,0\"><b>Removal &amp; Installation:<\/b> Gently twist the old tip counterclockwise to remove; align and twist the new SRP-4 Tip Set clockwise to install securely (avoid overtightening).<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"11,2,0\"><b>Calibration Check:<\/b> Always perform a Calibration Check with a standard plate immediately after SRP-4 Tip Replacement to verify the <span class=\"math-inline\" data-math=\"\\pm 1\\%\">\u00a01%<\/span>\u00a0accuracy.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"11,3,0\"><b>Post-Use Care:<\/b> Wipe the tip surface with a clean cloth or Nylon Brush after each use to remove residual copper powder or contaminants.<\/p>\n<\/li>\n<\/ol>\n<h2 data-path-to-node=\"12\">Procurement and Industry Value<\/h2>\n<p data-path-to-node=\"13\">For PCB factories, managing the supply of <b>Hitachi SRP-4 Tips<\/b> is vital for continuous quality control.<\/p>\n<ul data-path-to-node=\"14\">\n<li>\n<p data-path-to-node=\"14,0,0\"><b>Sourcing:<\/b> Purchasers often look for an authorized Hitachi SRP-4 Tips supplier or SRP-4 Tips manufacturer to ensure they receive high-purity OEM SRP-4 Tips. They may also search for SRP-4 Tips bulk purchase or SRP-4 tips wholesale options to reduce unit costs.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"14,1,0\"><b>Value:<\/b> By simplifying maintenance and ensuring continuous, high-precision measurement, the SRP-4 probe replacement tips directly reduce copper thickness-related rejects and support compliance with international standards (IPC, RoHS, REACH).<\/p>\n<\/li>\n<\/ul>\n<div>\n<div>\n<h2><strong>FAQ<\/strong><\/h2>\n<div><strong>Q1: Are these tips compatible with all SRP-4 probe versions?<\/strong><\/div>\n<div>A1: Yes, they are compatible with all SRP-4 probe models matched with CMI563\/CMI700\/CMI760 testers, consistent with Hitachi\u2019s original design.<\/div>\n<div><\/div>\n<div><strong>Q2: How often should the replacement tips be changed?<\/strong><\/div>\n<div>A2: It depends on usage frequency\u2014typically every 3\u20136 months for 8-hour daily use. If the tester shows data deviation (after calibration) or the tip is visibly worn, replace it immediately.<\/div>\n<div><\/div>\n<div><strong>Q3: Can third-party cleaning tools be used for the tips?<\/strong><\/div>\n<div>A3: We recommend using our Nylon Brush\u2014its soft bristles avoid scratching the crystal surface; rough tools may damage the tip and affect measurement accuracy.<\/div>\n<div><\/div>\n<div><strong>Q4: Is there a warranty for the replacement tips?<\/strong><\/div>\n<div>A4: We provide a 3-month warranty. If the tip has quality issues (e.g., inaccurate measurement) within the warranty period (non-human damage), we offer free replacement.<\/div>\n<div><\/div>\n<div><strong>Q5: Can the tips be used for hole copper thickness testing?<\/strong><\/div>\n<div>A5: No, they are only for SRP-4 probe (surface copper testing). For hole copper testing, please use our ETP Probe with matching replacement parts.<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Hitachi SRP-4 tips is a wearable, high-purity conductive probe with micro-resistance capabilities, designed for quick replacement to maintain high accuracy in measuring copper thickness on PCB surfaces.<\/p>\n<p><strong>Model\uff1a<\/strong>SRP-4 Replacement Tips<br \/>\n<strong>Core Material:\u00a0 <\/strong>High-purity crystal<br \/>\n<strong>Compatible Probe\uff1a<\/strong>SRP-4 probe<\/p>","protected":false},"featured_media":1171,"template":"","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_brand":[],"product_cat":[61,64],"product_tag":[],"class_list":{"0":"post-1164","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-test-equipment","7":"product_cat-srp-4-tips","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple","14":"entry","15":"content-bg","16":"loop-entry"},"taxonomy_info":{"product_cat":[{"value":61,"label":"Test equipment"},{"value":64,"label":"Hitachi SRP-4 Tips"}]},"featured_image_src_large":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/SRP-4-tips.webp",500,500,false],"author_info":[],"comment_info":"","_links":{"self":[{"href":"https:\/\/welleltron.com\/ru\/wp-json\/wp\/v2\/product\/1164","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/welleltron.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/welleltron.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/welleltron.com\/ru\/wp-json\/wp\/v2\/media\/1171"}],"wp:attachment":[{"href":"https:\/\/welleltron.com\/ru\/wp-json\/wp\/v2\/media?parent=1164"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/welleltron.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1164"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/welleltron.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1164"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/welleltron.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1164"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}