{"id":1277,"date":"2025-12-05T08:02:36","date_gmt":"2025-12-05T08:02:36","guid":{"rendered":"https:\/\/welleltron.com\/?post_type=product&#038;p=1277"},"modified":"2026-11-03T11:25:42","modified_gmt":"2026-11-03T11:25:42","slug":"cmi165-thickness","status":"publish","type":"product","link":"https:\/\/welleltron.com\/fr\/test-equipment\/thickness-gauges\/cmi165-thickness\/","title":{"rendered":"Hitachi CMI165 Copper Thickness Tester"},"content":{"rendered":"<h2 data-path-to-node=\"4\">1. Overview of the Hitachi CMI165<\/h2>\n<p data-path-to-node=\"5\">The <b data-path-to-node=\"5\" data-index-in-node=\"4\">Hitachi CMI165<\/b> is a specialized <b data-path-to-node=\"5\" data-index-in-node=\"37\">digital thickness gauge<\/b> that measures copper thickness on both rigid and flexible PCB materials. Unlike standard <a href=\"https:\/\/welleltron.com\/fr\/thickness-gauges\/\">coating thickness gauges<\/a> that might struggle with the conductivity of copper over various substrates, the CMI 165 is &#8220;substrate independent.&#8221; This means the thickness reading is not influenced by the laminate thickness or any copper layers on the opposite side of the board.<\/p>\n<p data-path-to-node=\"6\">Designed with portability in mind, this <b data-path-to-node=\"6\" data-index-in-node=\"40\">thickness gauge meter<\/b> allows for rapid testing directly on the production line. Whether you are auditing incoming copper-clad laminates (CCL) or checking the thickness of pcb board surfaces after the plating process, the CMI 165 provides the high precision thickness data required for high-reliability applications.<\/p>\n<h2 data-path-to-node=\"8\">2. Core Functionality: Micro-Resistance Technology<\/h2>\n<p data-path-to-node=\"9\">The technical heart of the Hitachi CMI165 is its use of the Four-Point Probe micro-resistance method. This is the gold standard for measuring conductive layers on non-conductive substrates.<\/p>\n<h3 data-path-to-node=\"12\">Key Features of the CMI165:<\/h3>\n<ul data-path-to-node=\"13\">\n<li>\n<p data-path-to-node=\"13,0,0\"><b data-path-to-node=\"13,0,0\" data-index-in-node=\"0\">Automatic Temperature Compensation:<\/b> Resistance is affected by temperature. The CMI 165 automatically adjusts its readings based on the ambient temperature, ensuring the <b data-path-to-node=\"13,0,0\" data-index-in-node=\"169\">thickness units<\/b> remain consistent in both air-conditioned labs and hot plating shops.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"13,1,0\"><b data-path-to-node=\"13,1,0\" data-index-in-node=\"0\">Dual Mode Capability:<\/b> The device can measure both Electroless Copper and <b data-path-to-node=\"13,1,0\" data-index-in-node=\"73\">Electrodeposited Copper<\/b>, with user-selectable settings to account for the differing conductivity of these materials.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"13,2,0\"><b data-path-to-node=\"13,2,0\" data-index-in-node=\"0\">Digital Gauge Meter Display:<\/b> The large, backlit <b data-path-to-node=\"13,2,0\" data-index-in-node=\"48\">gauge meter digital<\/b> screen allows for easy reading in dark environments, displaying values in mils.<\/p>\n<\/li>\n<\/ul>\n<h2 data-path-to-node=\"15\">3. Industrial Applications in Electronics Manufacturing<\/h2>\n<p data-path-to-node=\"16\">The CMI165 is an essential <b data-path-to-node=\"16\" data-index-in-node=\"28\">thickness gauge tool<\/b> across several stages of the PCB lifecycle.<\/p>\n<h3 data-path-to-node=\"17\">Quality Control in PCB Fabrication<\/h3>\n<p data-path-to-node=\"18\">During the plating process, it is easy for copper to be distributed unevenly. Using the CMI 165 for pcb thickness measurement at multiple points on a panel allows engineers to identify &#8220;thin spots&#8221; before the board moves to the etching stage. This prevents the creation of weak traces that could lead to circuit failure.<\/p>\n<h3 data-path-to-node=\"19\">Incoming Material Inspection<\/h3>\n<p data-path-to-node=\"20\">Manufacturers must verify that the <b data-path-to-node=\"20\" data-index-in-node=\"35\">standard pcb board thickness<\/b> of the copper foil matches the supplier&#8217;s specifications. The CMI165 acts as a reliable <a href=\"https:\/\/welleltron.com\/fr\/blog\/measure-pth-copper-thickness-cmi700\/\"><b data-path-to-node=\"20\" data-index-in-node=\"153\">thickness measurement instrument<\/b><\/a> for auditing raw materials, ensuring that the <b data-path-to-node=\"20\" data-index-in-node=\"232\">standard pcb thickness<\/b> (such as 0.5oz or 1oz copper) is accurate before production begins.<\/p>\n<h3 data-path-to-node=\"21\">Surface Finishing Industry<\/h3>\n<p data-path-to-node=\"22\">For boards that require precious metal finishing, the base copper thickness must be correct. The CMI165 is a versatile thickness tool that ensures the foundation is solid before gold, silver, or tin is applied.<\/p>\n<h2 data-path-to-node=\"24\">4. Technical Characteristics and Data Integrity<\/h2>\n<p data-path-to-node=\"25\">The CMI 165 is built for precision. Its data characteristics ensure that it remains a trusted thickness measurement tool for aerospace and medical electronics.<\/p>\n<ul data-path-to-node=\"26\">\n<li>\n<p data-path-to-node=\"26,0,0\"><b data-path-to-node=\"26,0,0\" data-index-in-node=\"0\">High Resolution:<\/b> The <b data-path-to-node=\"26,0,0\" data-index-in-node=\"21\">digital thickness gauge<\/b> provides readings down to 0.01 mils or 0.1 .<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"26,1,0\"><b data-path-to-node=\"26,1,0\" data-index-in-node=\"0\">Repeatability:<\/b> It offers exceptional consistency, with typical repeatability within 1% for standard electrodeposited copper.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"26,2,0\"><b data-path-to-node=\"26,2,0\" data-index-in-node=\"0\">Measurement Units:<\/b> Users can easily toggle between different <b data-path-to-node=\"26,2,0\" data-index-in-node=\"61\">thickness measurement units<\/b> (metric vs. imperial) to match customer requirements.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"26,3,0\"><b data-path-to-node=\"26,3,0\" data-index-in-node=\"0\">Calibration Memory:<\/b> The device can store a <a href=\"https:\/\/welleltron.com\/fr\/calibration-standard-plate\/\"><b data-path-to-node=\"26,3,0\" data-index-in-node=\"43\">Calibration Standard<\/b><\/a> profile, making it easy to reset the device to factory or user-defined accuracy levels.<\/p>\n<\/li>\n<\/ul>\n<table style=\"width: 486.5pt; border: none;\">\n<tbody>\n<tr>\n<td><\/td>\n<td>CMI95M<\/td>\n<td>CMI165<\/td>\n<td>CMI511(CMI500)<\/td>\n<td>CMI563<\/td>\n<td>CMI760(CMI700)<\/td>\n<\/tr>\n<tr>\n<td>Technique<\/td>\n<td>Microresistance<\/td>\n<td>microresistance<\/td>\n<td>Eddy curreny<\/td>\n<td>microresistance<\/td>\n<td>microresistance<\/td>\n<\/tr>\n<tr>\n<td>Copper Foil<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>Copper Clad Laminate(CCL)<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>Copper-Surface<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>Copper-Fineline<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<\/tr>\n<tr>\n<td>Copper Thru-hole<\/td>\n<td>\u00d7<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u00d7<\/td>\n<td>optional<\/td>\n<\/tr>\n<tr>\n<td>Temperature Compensation<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u221a<\/td>\n<td>\u00d7<\/td>\n<td>\u221a (ETP Probe)<\/td>\n<\/tr>\n<tr>\n<td>Replacement Probe Tip<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u00d7<\/td>\n<td>\u221a<\/td>\n<td>\u221a (SRP-4 Probe)<\/td>\n<\/tr>\n<tr>\n<td>Unit Selection<\/td>\n<td>oz\u00a0or um<\/td>\n<td>mil or um<\/td>\n<td>mil or um<\/td>\n<td>mil or um<\/td>\n<td>mil or um<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Thickness Range<\/td>\n<td>8 indicator lights<\/p>\n<p>1\/8-4 oz<\/p>\n<p>5-140\u00a0um<\/td>\n<td>Electroless Cu<\/p>\n<p>0.01-0.5 mil<\/p>\n<p>0.25-12.7 um<\/p>\n<p>Electroplated Cu<\/p>\n<p>0.1-10 mil<\/p>\n<p>2-254 um<\/td>\n<td>0.08-4.0 mil<\/p>\n<p>2-102 um<\/td>\n<td>Electroless Cu<\/p>\n<p>0.01-0.5 mil<\/p>\n<p>0.25-12.7 um<\/p>\n<p>Electroplated Cu<\/p>\n<p>0.1-6 mil<\/p>\n<p>3-152 um<\/td>\n<td>Surface Cu<\/p>\n<p>0.01-10 mil<\/p>\n<p>0.25-254 um<\/p>\n<p>Thru-hole Cu<\/p>\n<p>0.05-4 mil<\/p>\n<p>1-102um<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"font-weight: 400;\">\n<h2>FAQ<\/h2>\n<p><strong>1. Which probe does the CMI165 use?<\/strong><\/p>\n<p>The brochure identifies the <a href=\"https:\/\/welleltron.com\/fr\/test-equipment\/srp-4-probe\/hitachi-srp-4-probe\/\"><strong>SRP-T1 probe<\/strong><\/a>, featuring a replaceable tip and illuminated measurement area. Confirm replacement-part compatibility using the instrument\u2019s model and serial number.<\/p>\n<p><strong>2. How does the CMI165 measure copper thickness?<\/strong><\/p>\n<p>It uses a four-point electrical resistance method, also called microresistance. The probe contacts the copper surface, and the instrument converts the electrical measurement into a thickness reading. It is not an XRF analyzer.<\/p>\n<p><strong>3. What is the measurement range of the CMI165?<\/strong><\/p>\n<p>Hitachi\u2019s brochure lists 0.25\u201312.7 \u00b5m for electroless copper and 2\u2013254 \u00b5m for electroplated copper. Confirm the applicable range for your instrument configuration and sample before ordering.<\/p>\n<p><strong>4. Can the CMI165 measure copper inside plated through-holes?<\/strong><\/p>\n<p>The CMI165 is intended for surface and trace measurements. Do not assume its surface probe can measure hole-wall copper. For plated through-holes, specify a dedicated measurement system and provide the hole diameter, board thickness, and expected copper thickness.<\/p>\n<p><strong>5. Can the CMI165 measure fine copper traces?<\/strong><\/p>\n<p>Hitachi specifies etched traces as narrow as 204 \u00b5m. Suitability still depends on the sample geometry and correct probe placement.<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Hitachi CMI165 Copper Thickness Tester is a specialized, micro-resistance-based instrument designed for high-resolution, non-destructive measurement of ultra-thin copper thickness on PCB surfaces, often used for quality control in HDI manufacturing.<\/p>","protected":false},"featured_media":2161,"template":"","meta":{"_uag_custom_page_level_css":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_brand":[],"product_cat":[80,61],"product_tag":[],"class_list":["post-1277","product","type-product","status-publish","has-post-thumbnail","product_cat-thickness-gauges","product_cat-test-equipment","first","instock","virtual","purchasable","product-type-simple","entry","content-bg","loop-entry"],"taxonomy_info":{"product_cat":[{"value":80,"label":"Hitachi Thickness Gauges"},{"value":61,"label":"Test equipment"}]},"featured_image_src_large":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2.png",850,850,false],"author_info":[],"comment_info":"","spectra_custom_meta":{"rank_math_internal_links_processed":["1","1","1"],"_regular_price":["3300"],"total_sales":["0"],"_tax_status":["taxable"],"_tax_class":[""],"_manage_stock":["no"],"_backorders":["no"],"_sold_individually":["no"],"_virtual":["yes"],"_downloadable":["no"],"_product_image_gallery":["2164,2160,2162,2163"],"_download_limit":["-1"],"_download_expiry":["-1"],"_thumbnail_id":["2161"],"_stock":[null],"_stock_status":["instock"],"_wc_average_rating":["0"],"_wc_review_count":["0"],"_product_version":["11.2.0"],"_price":["3300"],"rank_math_seo_score":["77"],"_wp_page_template":["default"],"rank_math_primary_product_brand":["0"],"rank_math_primary_product_cat":["80"],"_kad_post_transparent":["default"],"_kad_post_layout":["default"],"_kad_post_content_style":["default"],"_kad_post_vertical_padding":["default"],"rank_math_title":["Hitachi CMI165 PCB Thickness Tester"],"rank_math_focus_keyword":["CMI165,Thickness Gauges"],"_wpb_gqb_disable":["no"],"_edit_lock":["1793706073:1"],"_edit_last":["1"],"_wp_old_slug":["hitachi-cmi165-pcb-thickness-tester"],"litespeed_vpi_list":["a:9:{i:0;s:29:\"cropped-welleltron_logo-1.png\";i:1;s:20:\"CMI165-2-600x600.png\";i:2;s:24:\"CMI165\u65e5\u7acb-600x600.png\";i:3;s:20:\"CMI165-2-100x100.png\";i:4;s:24:\"CMI165\u65e5\u7acb-100x100.png\";i:5;s:20:\"CMI165-2-100x100.jpg\";i:6;s:19:\"CMI1651-100x100.png\";i:7;s:18:\"CMI165-100x100.png\";i:8;s:9:\"en_US.png\";}"],"_uagb_previous_block_counts":["a:90:{s:21:\"uagb\/advanced-heading\";i:0;s:15:\"uagb\/blockquote\";i:0;s:12:\"uagb\/buttons\";i:0;s:18:\"uagb\/buttons-child\";i:0;s:19:\"uagb\/call-to-action\";i:0;s:15:\"uagb\/cf7-styler\";i:0;s:11:\"uagb\/column\";i:0;s:12:\"uagb\/columns\";i:0;s:14:\"uagb\/container\";i:0;s:21:\"uagb\/content-timeline\";i:0;s:27:\"uagb\/content-timeline-child\";i:0;s:14:\"uagb\/countdown\";i:0;s:12:\"uagb\/counter\";i:0;s:8:\"uagb\/faq\";i:0;s:14:\"uagb\/faq-child\";i:0;s:10:\"uagb\/forms\";i:0;s:17:\"uagb\/forms-accept\";i:0;s:19:\"uagb\/forms-checkbox\";i:0;s:15:\"uagb\/forms-date\";i:0;s:16:\"uagb\/forms-email\";i:0;s:17:\"uagb\/forms-hidden\";i:0;s:15:\"uagb\/forms-name\";i:0;s:16:\"uagb\/forms-phone\";i:0;s:16:\"uagb\/forms-radio\";i:0;s:17:\"uagb\/forms-select\";i:0;s:19:\"uagb\/forms-textarea\";i:0;s:17:\"uagb\/forms-toggle\";i:0;s:14:\"uagb\/forms-url\";i:0;s:14:\"uagb\/gf-styler\";i:0;s:15:\"uagb\/google-map\";i:0;s:11:\"uagb\/how-to\";i:0;s:16:\"uagb\/how-to-step\";i:0;s:9:\"uagb\/icon\";i:0;s:14:\"uagb\/icon-list\";i:0;s:20:\"uagb\/icon-list-child\";i:0;s:10:\"uagb\/image\";i:0;s:18:\"uagb\/image-gallery\";i:0;s:13:\"uagb\/info-box\";i:0;s:18:\"uagb\/inline-notice\";i:0;s:11:\"uagb\/lottie\";i:0;s:21:\"uagb\/marketing-button\";i:0;s:10:\"uagb\/modal\";i:0;s:18:\"uagb\/popup-builder\";i:0;s:16:\"uagb\/post-button\";i:0;s:18:\"uagb\/post-carousel\";i:0;s:17:\"uagb\/post-excerpt\";i:0;s:14:\"uagb\/post-grid\";i:0;s:15:\"uagb\/post-image\";i:0;s:17:\"uagb\/post-masonry\";i:0;s:14:\"uagb\/post-meta\";i:0;s:18:\"uagb\/post-taxonomy\";i:0;s:18:\"uagb\/post-timeline\";i:0;s:15:\"uagb\/post-title\";i:0;s:20:\"uagb\/restaurant-menu\";i:0;s:26:\"uagb\/restaurant-menu-child\";i:0;s:11:\"uagb\/review\";i:0;s:12:\"uagb\/section\";i:0;s:14:\"uagb\/separator\";i:0;s:11:\"uagb\/slider\";i:0;s:17:\"uagb\/slider-child\";i:0;s:17:\"uagb\/social-share\";i:0;s:23:\"uagb\/social-share-child\";i:0;s:16:\"uagb\/star-rating\";i:0;s:23:\"uagb\/sure-cart-checkout\";i:0;s:22:\"uagb\/sure-cart-product\";i:0;s:15:\"uagb\/sure-forms\";i:0;s:22:\"uagb\/table-of-contents\";i:0;s:9:\"uagb\/tabs\";i:0;s:15:\"uagb\/tabs-child\";i:0;s:18:\"uagb\/taxonomy-list\";i:0;s:9:\"uagb\/team\";i:0;s:16:\"uagb\/testimonial\";i:0;s:14:\"uagb\/wp-search\";i:0;s:19:\"uagb\/instagram-feed\";i:0;s:10:\"uagb\/login\";i:0;s:17:\"uagb\/loop-builder\";i:0;s:18:\"uagb\/loop-category\";i:0;s:20:\"uagb\/loop-pagination\";i:0;s:15:\"uagb\/loop-reset\";i:0;s:16:\"uagb\/loop-search\";i:0;s:14:\"uagb\/loop-sort\";i:0;s:17:\"uagb\/loop-wrapper\";i:0;s:13:\"uagb\/register\";i:0;s:19:\"uagb\/register-email\";i:0;s:24:\"uagb\/register-first-name\";i:0;s:23:\"uagb\/register-last-name\";i:0;s:22:\"uagb\/register-password\";i:0;s:30:\"uagb\/register-reenter-password\";i:0;s:19:\"uagb\/register-terms\";i:0;s:22:\"uagb\/register-username\";i:0;}"],"_uag_css_file_name":["uag-css-1277.css"],"_elementor_page_assets":["a:0:{}"],"_uag_page_assets":["a:9:{s:3:\"css\";s:260:\".uag-blocks-common-selector{z-index:var(--z-index-desktop) !important}@media(max-width: 976px){.uag-blocks-common-selector{z-index:var(--z-index-tablet) !important}}@media(max-width: 767px){.uag-blocks-common-selector{z-index:var(--z-index-mobile) !important}}\";s:2:\"js\";s:0:\"\";s:18:\"current_block_list\";a:26:{i:0;s:12:\"core\/heading\";i:1;s:9:\"core\/list\";i:2;s:14:\"core\/list-item\";i:3;s:9:\"core\/code\";i:4;s:10:\"core\/group\";i:5;s:12:\"core\/columns\";i:6;s:14:\"core\/tag-cloud\";i:7;s:17:\"core\/social-links\";i:8;s:10:\"core\/video\";i:9;s:15:\"core\/media-text\";i:10;s:14:\"core\/paragraph\";i:11;s:10:\"core\/audio\";i:12;s:10:\"core\/image\";i:13;s:10:\"core\/verse\";i:14;s:14:\"core\/pullquote\";i:15;s:17:\"core\/preformatted\";i:16;s:12:\"core\/details\";i:17;s:14:\"core\/page-list\";i:18;s:18:\"core\/legacy-widget\";i:20;s:16:\"core\/social-link\";i:21;s:12:\"kadence\/form\";i:22;s:14:\"kadence\/search\";i:23;s:16:\"kadence\/iconlist\";i:24;s:16:\"kadence\/listitem\";i:25;s:12:\"kadence\/icon\";i:26;s:19:\"kadence\/single-icon\";}s:8:\"uag_flag\";b:0;s:11:\"uag_version\";s:10:\"1794059908\";s:6:\"gfonts\";a:0:{}s:10:\"gfonts_url\";s:0:\"\";s:12:\"gfonts_files\";a:0:{}s:14:\"uag_faq_layout\";b:0;}"]},"uagb_featured_image_src":{"full":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2.png",850,850,false],"thumbnail":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2-150x150.png",150,150,true],"medium":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2-300x300.png",300,300,true],"medium_large":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2-768x768.png",768,768,true],"large":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2.png",850,850,false],"1536x1536":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2.png",850,850,false],"2048x2048":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2.png",850,850,false],"trp-custom-language-flag":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2-12x12.png",12,12,true],"woocommerce_thumbnail":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2-300x300.png",300,300,true],"woocommerce_single":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2-600x600.png",600,600,true],"woocommerce_gallery_thumbnail":["https:\/\/welleltron.com\/wp-content\/uploads\/2025\/12\/CMI165-2-100x100.png",100,100,true]},"uagb_author_info":{"display_name":"lucaismilelove@gmail.com","author_link":"https:\/\/welleltron.com\/fr\/blog\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"Hitachi CMI165 Copper Thickness Tester is a specialized, micro-resistance-based instrument designed for high-resolution, non-destructive measurement of ultra-thin copper thickness on PCB surfaces, often used for quality control in HDI manufacturing.","_links":{"self":[{"href":"https:\/\/welleltron.com\/fr\/wp-json\/wp\/v2\/product\/1277","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/welleltron.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/welleltron.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/welleltron.com\/fr\/wp-json\/wp\/v2\/media\/2161"}],"wp:attachment":[{"href":"https:\/\/welleltron.com\/fr\/wp-json\/wp\/v2\/media?parent=1277"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/welleltron.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1277"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/welleltron.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1277"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/welleltron.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1277"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}