Hitachi SRP-4 tips

$230.00

Hitachi SRP-4 tips is a wearable, high-purity conductive probe with micro-resistance capabilities, designed for quick replacement to maintain high accuracy in measuring copper thickness on PCB surfaces.

Model:SRP-4 Replacement Tips
Core Material:  High-purity crystal
Compatible Probe:SRP-4 probe

Hitachi SRP-4 tips Overview

Hitachi SRP-4 tips (also called Probe Tips or Srp-4 Probe Tips) are core consumable accessories designed for Hitachi SRP-4 probes—key components of CMI series PCB Cooper Thickness Testers (including CMI563, CMI700, CMI760). Made with high-quality crystal materials, these replacement tips maintain the same measurement precision as the original probe, ensuring consistent accuracy in PCB surface copper thickness testing. As part of our one-stop PCB testing solutions, they seamlessly match other products like SRP-4 probe, ETP Probe (for hole copper testing), and Nylon brush (for tip cleaning), providing comprehensive support for PCB production quality control.

Technical Specifications and Material Science

The performance of the SRP-4 Contact Tips is directly tied to the specialized materials and strict manufacturing tolerances provided by Hitachi High-Tech SRP-4 Tips.

SpecificationDetailSignificance
Model/CompatibilitySRP-4 Replacement Tips$100 compatible with the SRP-4 probe body used on CMI563/CMI700 Tips.
Core MaterialHigh-purity crystal (Often a specialized Conductive Alloy Tips blend)Ensures stable Micro-Resistance Tips performance and consistent eddy current induction.
Measurement PrincipleFour-Point Probe TipsMaintains the accuracy needed for Copper Thickness Testing Tips.
ResolutionDown to 0.001mils (<1μm)Supports high-precision testing for ultra-thin Electroless Copper layers.
Applicable Range0.25 μm to 152μmCovers the entire spectrum of PCB Measurement Tips requirements, from fine lines to thick electroplating.

Key Features and Cost Advantages

Choosing OEM SRP-4 Tips over Generic SRP-4 Tips offers significant operational and financial benefits for purchasers looking at the SRP-4 Tips price / cost.

FeatureAdvantageValue to Purchaser
Seamless Compatibility100% compatibility with CMI563/CMI700 Tips testers.Eliminates performance issues associated with Non-OEM SRP-4 Tips and guarantees reliable PCB Measurement Tips results.
Cost EfficiencyAllows replacement of just the tip (SRP-4 Tips Refill), not the entire probe assembly.Cuts annual probe maintenance costs by over 50% compared to models requiring full probe replacement.
Quick TurnaroundOn-site replacement can be completed by operators in 2–3 minutes.Minimizes tester downtime, ensuring production continuity and efficiency.
Consistent AccuracyOEM SRP-4 Tips maintain the original  1% accuracy standard.Prevents costly manufacturing rejects due to inaccurate copper thickness data.

Application Scenarios

These precision SRP-4 Probe Tips are essential across high-reliability Electronics Manufacturing sectors:

  • High-Density Interconnect (HDI) Production: Critical for accurately measuring ultra-thin copper layers (<1 μm) used in micro-vias, where the SRP-4 Crystal Tips may be preferred.

  • Automotive/Aerospace PCB: Used in PCB Quality Control (QC) to verify that heavy Electrodeposited Copper meets stringent durability standards.

  • R&D and Laboratory Testing: Provides reliable, traceable data for new process development, relying on the stability of the SRP-4 Tip Set.

Replacement and Maintenance Protocol

Proper Probe Tip Maintenance ensures the longevity of the SRP-4 Thickness Probe and the accuracy of the CMI gauge.

  1. Preparation: Turn off the tester and disconnect the SRP-4 probe. Clean the probe base with a Nylon Brush.

  2. Removal & Installation: Gently twist the old tip counterclockwise to remove; align and twist the new SRP-4 Tip Set clockwise to install securely (avoid overtightening).

  3. Calibration Check: Always perform a Calibration Check with a standard plate immediately after SRP-4 Tip Replacement to verify the  1% accuracy.

  4. Post-Use Care: Wipe the tip surface with a clean cloth or Nylon Brush after each use to remove residual copper powder or contaminants.

Procurement and Industry Value

For PCB factories, managing the supply of Hitachi SRP-4 Tips is vital for continuous quality control.

  • Sourcing: Purchasers often look for an authorized Hitachi SRP-4 Tips supplier or SRP-4 Tips manufacturer to ensure they receive high-purity OEM SRP-4 Tips. They may also search for SRP-4 Tips bulk purchase or SRP-4 tips wholesale options to reduce unit costs.

  • Value: By simplifying maintenance and ensuring continuous, high-precision measurement, the SRP-4 probe replacement tips directly reduce copper thickness-related rejects and support compliance with international standards (IPC, RoHS, REACH).

FAQ

Q1: Are these tips compatible with all SRP-4 probe versions?
A1: Yes, they are compatible with all SRP-4 probe models matched with CMI563/CMI700/CMI760 testers, consistent with Hitachi’s original design.
Q2: How often should the replacement tips be changed?
A2: It depends on usage frequency—typically every 3–6 months for 8-hour daily use. If the tester shows data deviation (after calibration) or the tip is visibly worn, replace it immediately.
Q3: Can third-party cleaning tools be used for the tips?
A3: We recommend using our Nylon Brush—its soft bristles avoid scratching the crystal surface; rough tools may damage the tip and affect measurement accuracy.
Q4: Is there a warranty for the replacement tips?
A4: We provide a 3-month warranty. If the tip has quality issues (e.g., inaccurate measurement) within the warranty period (non-human damage), we offer free replacement.
Q5: Can the tips be used for hole copper thickness testing?
A5: No, they are only for SRP-4 probe (surface copper testing). For hole copper testing, please use our ETP Probe with matching replacement parts.